Open-plan offices
Full-height runs creating cellular offices within a floorplate while keeping daylight moving through the space.
Glass & Partitions
Partition systems that divide a floorplate without taking its daylight — frameless butt-jointed runs, slim framed systems, and double-glazed acoustic rooms where confidentiality is a genuine requirement.
Who this work is for
In practice
Almost every partition enquiry arrives with the same brief: keep it open, keep it light, but make it quieter. Those requirements pull against each other, and the honest conversation is about how much quieter — because the answer changes the specification and the budget with it.
A single-glazed frameless partition in 10mm or 12mm toughened glass is the lightest-looking option and by far the most common. It takes the edge off normal conversation, but it will not contain a raised voice or a speakerphone. The weak points are never the glass — they are the joints: the butt joint between panes, the gap at the head, and the door. A dry butt joint leaks sound badly; a properly filled clear silicone joint helps noticeably.
Where the requirement is real acoustic separation — a director’s office, a consulting room, an HR meeting room — the answer is a double-glazed partition with two panes of different thickness, because two identical panes resonate together and undo much of the benefit. The perimeter matters just as much: acoustic seals at head and jambs, a sealed floor line, and an acoustic door with a drop seal. A double-glazed partition with a poorly sealed head performs worse than a well-sealed single-glazed one.
Then there is the ceiling, which is where most partition packages quietly disappoint. A partition that stops at a suspended ceiling leaves an open plenum above it, and sound travels straight over the top through the void. If acoustic performance genuinely matters, the partition has to reach the soffit or the plenum has to be baffled. That is a coordination question rather than a glass question, and it is the reason we ask to see the reflected ceiling plan before we quote.
A partition that stops at the suspended ceiling leaves an open plenum. Sound travels straight over the top.
Where it is used
The situations this work most often solves. If yours is not listed, it is still worth asking.
Full-height runs creating cellular offices within a floorplate while keeping daylight moving through the space.
Double-glazed acoustic systems with sealed perimeters and acoustic door sets where confidentiality is required.
Frosted or manifested glazing giving privacy without making a small treatment room feel enclosed.
Feature glazing that defines arrival without closing the space in.
Dividing stock, staff and workshop areas from the sales floor without losing sightlines.
Turning an open shell into a fitted floorplate, coordinated with the base-build services.
Design possibilities
Finishes, configurations and specification choices available on this work. Samples can be provided before anything is committed.
Fully frameless butt-jointed glass, slim aluminium framed systems, or black steel-look framing for an industrial finish.
Clear, low-iron for maximum clarity, tinted, acid-etched, sandblasted, or digitally printed with your own artwork.
Frosted bands, gradient patterns, logos or dot matrices — required for safety, and an opportunity for branding.
Frameless leaves on floor springs, framed acoustic doors with drop seals, or sliding and barn-style doors where swing space is tight.
Magnetically operated blinds sealed inside the cavity, or room-side blinds where long-term serviceability matters more.
Satin stainless, polished chrome, matt black or brushed brass on patches, handles and channels.
Why it matters
Rooms borrow light from the floorplate, which changes how enclosed a deep-plan office feels.
We tell you what a given build-up will and will not contain, before it is installed rather than after.
Runs are set out from measured wall positions, ceiling grid and floor levels — not from the drawing.
Framed systems can be dismantled and reset when the floorplate changes, which most tenants need eventually.
Technical
Final specification is confirmed at survey, against the actual opening, exposure and use.
How we do it
The steps specific to this work — not a generic checklist.
We ask what each room is for. “Quieter” and “confidential” need very different systems, and the difference is significant.
Before any glass is sized, we check the partition line against the ceiling grid, sprinklers and detectors.
Panel widths, door positions and joint lines confirmed on a drawing so nothing is decided on site.
Measured once ceiling and floor levels are real, which is what makes the head and floor details fit.
Channels levelled, panes set, joints siliconed, doors hung, closers adjusted and blinds tested.
Send drawings, dimensions or a photograph of the space. For anything beyond a straightforward replacement we will arrange a survey, because measuring it ourselves is the only way to quote a price that will not move.
Questions
A single-glazed frameless partition takes the edge off normal conversation but will not contain a raised voice or a speakerphone. For real confidentiality you need a double-glazed system with panes of differing thickness, fully sealed perimeters, an acoustic door — and the partition must reach the soffit rather than stopping at a suspended ceiling.
Frameless looks cleaner and is usually preferred for reception and showpiece areas. Framed costs less and can be dismantled and reset when the layout changes, which most growing businesses need within a few years. Acoustically they perform similarly at single glazing.
Yes, always. Creating rooms out of an open floorplate changes the coverage requirement, and that has to be re-planned by the M&E contractor. We flag it during setting-out because it is the most common cause of a failed inspection after partitions go in.
They look excellent and never collect dust, but they cannot be serviced without opening the sealed unit, and they require double glazing whether or not you needed it acoustically. Room-side blinds cost a fraction and anyone can repair them. Both are legitimate — just decide deliberately.
Yes. Most partition work in occupied space is done in phases or outside working hours. Tell us the access constraints early, because it changes how we sequence fabrication and delivery.
Related work
Frameless toughened swing doors on floor springs, patch fittings or glass hinges.
Sandblasted and acid-etched glass for privacy, manifestation, branding and decorative panels.
Toughened safety glass cut, drilled and edge-worked to size, supplied loose or installed.
Bespoke glass, aluminium and metal pieces for non-standard sizes, unusual details and existing buildings that are not square.
Get in touch
Drawings, dimensions or just a photo of the space — whatever you have is enough to start.